How much gas does a boiler or furnace use? January and a whole year
How much gas a boiler or furnace uses in a 100 m² home in Glasgow, Manchester, London, Dublin, Boston and Minneapolis: in January and over a year.
Gas Boiler Defender guide
A condensing boiler only recovers the heat in the steam of its flue gases when the water coming back from the radiators is cool enough, below about 55 °C. With the flow at 80 °C it hardly condenses. Turning it down to 50-55 °C, if the home stays warm, saves 2 to 6 % of the heating gas; with weather compensation, more.
The flue gases of a boiler contain steam. When the water coming back from the radiators is cool, the steam condenses in the heat exchanger and gives up its heat: that is the extra a condensing boiler gets. When the water comes back hot, above about 55 °C, that heat goes out of the flue and the boiler works almost like an old non-condensing one.
| Flow and return water | Seasonal efficiency | Gas compared with 80/60 °C |
|---|---|---|
| 80 °C / 60 °C | 87.1 % | reference |
| 55 °C / 47 °C | 89.3 % | about −2.5 % |
| 45 °C / 39 °C | 92.8 % | about −6 % |
These are BRE's figures (S10TP-12) for a modulating boiler without weather compensation. With an outdoor sensor, which lowers the water temperature by itself when it is milder outside, you gain another 2 to 3 points; with an on/off thermostat you lose 1 to 2. In a 100 m² London home, going from 80/60 to 45/39 °C saves about 450 kWh, around £36 a year; in Dublin about €53.
This guide explains in plain words how to compare the gas of a natural gas boiler or furnace with the real cold. The figures are estimates made with Gas Boiler Defender's model: your home, your boiler and your habits can give different values. If you smell gas, get out, don't touch any switches and call from outside: UK 0800 111 999 (Northern Ireland 0800 002 001), Ireland 1800 20 50 50, US 911 or your gas company's emergency line. Only a qualified engineer works on the boiler and the gas supply.
Figures worked out on 19 November 2026 with the real cold of the winters from 2023/24 to 2025/26 (NASA POWER) and with the gas measured in British and US homes (NEED 2025, RECS 2020).
How much gas a boiler or furnace uses in a 100 m² home in Glasgow, Manchester, London, Dublin, Boston and Minneapolis: in January and over a year.
Gas bill so high? Estimated readings, a flow temperature too high, an old or oversized boiler, hot water, a furnace filter, a leaky home: causes and signs.
Gas Boiler Defender compares your gas with the real cold for free. The full report (£12.99, €14.99 or $14.99) shows whether the flow is too hot, what to change on the controls and the saving over a year.